Ask for a dimensioned end elevation and an installed roof section when you specify a gabled or flat louvered pergola. Read the highest fixed point, the clear height below the lowest relevant beam or fitting, and the space the louvers occupy as separate measurements. We use our freestanding APEX and NEO ALU as examples. Both have a nominal 4 × 3 m option, yet the drawings answer different questions about the roof, its supports and nearby obstructions.
NEO ALU flat-roof pergola on a terraceStart With One Datum and Two Views
Choose the Elevation That Shows the Roof Form
Start with the installation format, nominal size and operating system in a single drawing set. In this comparison we use a freestanding four-post manual configuration for each model. On a gable roof pergola, look toward the gable end to see the ridge and the two lower roof edges. Along an eave, the same pitched roof can present a nearly level edge. On a flat-roof pergola, find the elevation that shows the beam over the entrance or route you need to keep clear.
Use the aluminum louvered pergola range to shortlist roof forms. Check the post layout before comparing sizes. Our guide to pergola size, post positions and roof zones explains how to establish that layout. ISO’s guidance on views, sections and cuts gives the drawing terminology for asking for the view you need.
Set the Datum and Mark the Section Cut
Agree where zero sits on the project drawing. A terrace surface can finish above a support level, and a sloped surface can change elevation along a route. Mark the finished level at the actual measuring point. Put the height limit, eave or open window on that same datum. A section through the relevant beam or louver pivot can then show the two elements in the same vertical plane.
If you use drawings in different units, convert from the original marked value and keep track of the dimension endpoints. NIST’s exact inch-to-millimeter conversion is 25.4 mm per inch. If a dual-unit callout disagrees with its metric value, ask which value controls before sharing it with the installer.
Read the APEX Ridge and NEO ALU Beam Line
Find the Ridge and Eaves on APEX
Our APEX gabled aluminum louvered pergola uses a dual-slope roof with two louvered planes meeting at the ridge. The nominal 4 × 3 m dimension sheet marks 2,820 mm at the ridge and 2,400 mm at the eave line. These points are 420 mm apart vertically on the drawing. To answer a headroom question, ask for a dimension to the lowest installed beam face or fitting at the intended passage. Check the ridge against overhead limits and each eave against the nearby site feature.
Two views of the APEX series. The angled view reveals the ridge, while the eave-side view shows the level edge seen from that direction.
The same sheet marks 3,990 × 3,070 mm on the perspective view and 3,710 × 2,790 mm between the inside post faces on the elevations. Carry the label and its endpoints into your layout. If you need a fixing layout, obtain the dimensioned base-plate view that applies to your configuration. On a gable pergola, the end elevation shows the roof form and post opening together.
Read the Flat Roofline and Beam on NEO ALU
For our NEO ALU aluminum louvered pergola with a flat roofline, the product page lists the nominal 4 × 3 m freestanding option at 4,000 × 3,080 × 2,520 mm in L × D × H order. The H field gives the published model height. Ask for the installed dimension to the underside of the beam that crosses your chosen route, using the finished surface directly below it.
- Heights from the baseline on our dimensioned view.
- Read the eave and the lowest fixed underside as separate endpoints.
Designed and created by the Outdoor Creation team.
- H is the product page height field for the freestanding option.
- The beam underside pointer identifies the next measurement.
Designed and created by the Outdoor Creation team.
Simplified elevations. Carry the endpoint and datum with each dimension when comparing the roofs.
Designed and created by the Outdoor Creation team.
Our matching NEO ALU manual shows 3,938 × 3,023 mm across the outside post faces and 3,982 × 3,067 mm across the outside edges of the base plates. Use those views to see what the nominal size leaves unspecified. Keep the dimensions on the appropriate drawing layer when checking a terrace edge, planned opening or post position.
- 3,982 × 3,067 mm across the outer plate edges.
Designed and created by the Outdoor Creation team.
- 3,938 × 3,023 mm across the outside post faces.
- 3,706 × 2,791 mm between inside post faces.
Designed and created by the Outdoor Creation team.
Measure the footprint at the layer you need. Confirm the attachment detail for the selected site and order.
Designed and created by the Outdoor Creation team.
The same manual identifies 153 × 75 mm main beam sections on the long sides and 195 × 75 mm side beam sections on the short sides, stated here as depth × width. The beam section helps identify the part on an installed view. Measure to the actual underside of the beam or any lower fitting when the buyer needs an accessible passage or a clear opening.
- 1Long main beams. Each has a 153 × 75 mm section and receives the blade ends.
- 2Short side beams. Each has a 195 × 75 mm section and closes an end of the frame.
- 3Louver bank. Blade axes span between the long main beams.
- 4Posts and plates. The four corners locate the frame below the beam connections.
NEO ALU manual freestanding example. Selected blades are shown for orientation. Beam dimensions describe individual profiles.
Designed and created by the Outdoor Creation team.
Check the Louvers Through Their Full Travel
Separate Roof Pitch From Blade Rotation
Roof pitch describes the inclination of a fixed roof plane. Louver rotation describes how each blade turns about its pivot from a stated reference. For a pergola with a gable roof, request the reference for each roof bank. For a flat louvered roof, check the installed pivot position relative to the frame top. Both examples show a 166 × 34 mm louver profile. To compare where its edges move, use the blade outline with the installed pivot and permitted travel on each drawing.
Our NEO ALU manual shows the driven spindle meeting the long main beam, with the gearbox on the outside face and the link bar along the blade ends. That identifies where to ask for an installed section. The product page lists a series maximum opening of 135°. For this manual configuration, request the applicable reference, end positions and the full swept outline. Ask for the same evidence for the two roof banks on APEX. Our guide to aluminum louver shapes and edges explains what to read on a single blade profile.
- 1Long main beam at the louver ends.
- 2Driven spindle through the beam.
- 3Gearbox outside the main beam.
- 4Link bar along the inner side of the blade ends.
Designed and created by the Outdoor Creation team.
NEO ALU louver and beam junctionRelationship diagram of the selected manual example. Final trim and internal beam details are simplified. The product photo shows the blade-to-frame area from below.
Designed and created by the Outdoor Creation team.
- Use the closed blade position as a reference marked on the applicable drawing.
Designed and created by the Outdoor Creation team.
- Follow the near blade edge as it turns around the same pivot.
Designed and created by the Outdoor Creation team.
- Find the actual stop and full path for the selected configuration.
Designed and created by the Outdoor Creation team.
Illustrative positions. The blue dot follows the same edge. The applicable roof section establishes the rotation endpoints and full travel envelope.
Designed and created by the Outdoor Creation team.
Check Where the Moving Envelope Overlaps the Site
Draw the soffit, opening window or fixed screen on the roof plan. Where its projection approaches the roof, mark a section through the affected louver and the nearest edge of the obstruction. Include any movement of the site feature in the same check. For an opening window, show its limiting open position and the part of its swing relevant to the close approach. Compare the separation where the moving parts come closest and have the project team confirm the required clearance.
- Draw section A–A through the closest approach.
Designed and created by the Outdoor Creation team.
- 1Mark the nearest fixed obstruction at its project level.
- 2Show the full louver travel at that location.
Designed and created by the Outdoor Creation team.
Conceptual site example. Apply the actual geometry and required separation for your project.
Designed and created by the Outdoor Creation team.
Contact an aluminum pergola manufacturer for roof elevation drawings with your marked section line and the measurements you already have. Use the check below to identify the next view and the endpoints to mark.
Close the Drawing Checks Before Specification
Send Measured Site Constraints With the Chosen Layout
When you ask a louvered pergola factory for configuration drawing requests, include the model and nominal size, the intended post layout and control type, and one drawing with your finished levels and obstructions marked. A municipal building plan guide from Portland is an example of how plan, elevation and section work together in a drawing set. Ask your own project team which drawings it requires.
Bring both the heights and footprint onto the site drawing before ranking alternatives. A centered ridge can sit outside the projection of an existing eave even when the two levels look close on an elevation. A fitting near a doorway can also reduce usable headroom while the pergola meets the overall height limit. Record each decision with the location you checked.
| Drawing check | APEX · 4 × 3 m | NEO ALU · 4 × 3 m | Record before ordering |
|---|---|---|---|
| Fixed top | 2,820 mm at the ridge and 2,400 mm at the eave line on the dimension sheet. | 2,520 mm published overall H. | End elevations with marked endpoints and a common datum. |
| Clear below | Read the underside at the required route. | Identify which beam and any fitting crosses the route. | Minimum installed clearance along the route. |
| Plan extent | 3,990 × 3,070 mm on the perspective view. | 3,982 × 3,067 mm across outer plates in our manual. | Match the same plan endpoints for the site check. |
| Part profiles | 195 × 75 mm beam and 166 × 34 mm blade on the dimension sheet. | 153 × 75 mm main beam, 195 × 75 mm side beam and 166 × 34 mm blade in the manual. | Identify the part and ask how it sits in the installed roof. |
| Blade travel | Confirm the reference, stops and swept outline for each roof bank. | Series listing gives 135°. Confirm the manual configuration’s travel. | Installed section through the pivot at the overlap. |
Designed and created by the Outdoor Creation team.
Keep the Updated Drawing Set With the Order
Record the drawing revision, size, control and viewing direction for each check. If the finish level changes, the roof orientation is reversed or another drive is chosen, update the affected dimensions and request the matching documents again. Our pergola and outdoor structure manufacturing facility supports drawing discussions for the selected configuration. For other structures on the same site, start with our outdoor structure product overview and confirm their interfaces on the project drawings.
Frequently Asked Questions
What is a gabled louvered pergola?
It has two sloping roof planes that meet at a ridge. Confirm the roof and louver details for the selected model.
Where is the gable height measured from?
Read from the stated datum to the ridge point marked on the elevation. Confirm both endpoints before comparing the dimension with a project height limit.
Which height shows the clear space beneath a beam?
Use the dimension from the finished surface to the lowest fixed member or fitting that affects the route. Ask for the relevant installed section.
Can a pergola fit under existing eaves?
Check the measured eaves against the fixed roof and the louver travel where they overlap. Ask the project team to confirm the required clearance.
Does roof pitch show the louver opening angle?
Roof pitch describes the fixed roof plane. Opening angle describes blade rotation from a stated reference. Confirm the reference and limits for the selected configuration.
Does a flat roofline describe every internal level?
The roofline identifies the exterior profile. Ask for the installed section to confirm the levels of the beam, louvers and any internal falls.
Which drawings show the space needed for louver movement?
Ask for a section through the blade pivot and full travel envelope. Match it to the selected size, control and position of any site obstruction.
Which drawings should I request before ordering?
Request end and side elevations, an installed roof section and the applicable operation limits. Give the supplier the selected layout and measured site constraints.
Review Your Roof Configuration With Us
Share your preferred roof form, nominal size and any height or clearance constraints. We manufacture aluminum pergolas in our own factory and can review custom requirements with your project team. Send the relevant elevation or section so we can discuss the configuration.